Why Hot De-Ionized water? Hot "DI" water has become an attractive
replacement for chlorofluorocarbons (CFC's). CFC's are ozone depleting and
must be phased out of all manufacturing operations. Hot De-Ionized water provides
a more aggressive cleaning agent, will flash dry quickly and is "user friendly"
in terms of its disposal. Heated "DI" water has remarkable cleaning
properties and will not pollute the environment.

Eemax EX180DI "De-Ionized" Electric Tankless Water Heater Applications:
Microchip Manufacturing
Pharmaceutical production
High Tolerance Component Cleaning
Ultrasonic Cleaning
Spray Rinse Tank
Batch Chemical Mixing

Eemax EX180DI "De-Ionized" Electric Tankless Water Heater Features:
Cold or Hot water feed
Capable of Heating High Purity Water- state of the art materials used
in construction, rated for purity levels up to 18 MEG OHM.
Test Proven by independent analytical laboratory to maintain water purity.
Test conclusion verified no measurable contamination of water passing through
the Eemax heater. Test results available upon request.
Extensive Product Range- 3 kW, 120V through 32kW, three phase power available
Thermostatic Temperature Control Available- highly accurate micro processor
to deliver +/- 1°F outlet accuracy.
Compact size- Largest unit is 15-1/4"x12-1/4"x4-1/4"
Eliminate Deadlegs- unique flow activated design allows for constant
water movement, even when not heating.
Easy Installation- compact size, allows for installation close to point
of use.
Eemax EX180DI "De-Ionized" Single Heating Module Electric Tankless
Water Heater Specifications:
Dimensions - 12-1/4"x 15-1/4" x 7-1/4"
Weight - 20lbs
KW - 18kW
208/120V requires: 3 lives, 1 ground (earth) (no neutral)
480Y/277V requires: 3 lives, 1 neutral and 1 ground (earth)
Rise at 2.0 GPM - 61°F
Rise at 3.0 GPM - 41°F
Rise at 4.0 GPM - 31°F
Rise at 5.0 GPM - 25°F
Bottom water connections, 1/2" compression fitting (type 316 stainless
steel)
The voltage, amperage, and circuit breaker specifications must be met
for this heater to function. Please make sure all requirements are met before
purchasing this heater. Manufacturer's start up procedures must be observed.
All Eemax Three-Phase units are custom made to order and as such are, non-returnable and non-refundable. We urge you therefore to check your electrical supply, making sure all criteria for operating your Eemax water heater are met, especially that a neutral line is availablefor all 480Y/277V.
Options:
EX180DI 208/120V- no neutral leg, 18 kw, 50A/phase, 6AWG wire
EX180DI 480/277V- neutral leg required, 18 kw, 22A/phase, 10AWG wire
Turn On Options:
T2T=Staged Turn-on .7 GPM, max 3.5 GPM
T3=Parallel Turn-on 1.6 GPM, max 5GPM
Thermostatic Options:
S=Sanitation temperature setting 180°
FS=Factory set temperature setting (ambient 180°)
P=Ambient to 100°
Priced for EX180DI T2T S (208/120V- 50A/phase, Staged Turn-on, Sanitation
setting 180°)